To change the range you go in to the BEH MEASUREMENT CONTROL file in fileman and change the Low Value and High Value. Please see an inquiry below and how you would change the setting:
Select VA FileMan Option: INQuire to File Entries
Output from what File: OE/RR REPORT// BEH MEASUREMENT CONTROL
(40 entries)
Select BEH MEASUREMENT CONTROL: BLOOD PRESSURE BP
Another one:
Standard Captioned Output? Yes// (Yes)
Include COMPUTED fields: (N/Y/R/B): NO// BOTH Computed Fields and Record Number
(IEN)
NUMBER: 1 NAME: BLOOD PRESSURE
ABBREVIATION: BP RATE: YES
RATE HELP: GMRV-BLOOD PRESSURE RATE HELP
PCE ABBREVIATION: BP
RATE INPUT TRANSFORM: I ‘(“UNAVAILABLEPASSREFUSED”[$$UP^XLFSTR(X)) K:X’?2.3N0.
1″/”0.3N0.1″/”0.3N&(X’?2.3N0.1″/”0.3N) X I $D(X),X>0 K:$P(X,”/”,1)>300!($P(X,”/”
,2)>300)!(+$P(X,”/”,3)>300) X I $D(X),$P(X,”/”)’>$P(X,”/”,$L(X,”/”)) K X
LOW VALUE: 90/40 HIGH VALUE: 200/100
Enter or Edit File Entries
Print File Entries
Search File Entries
Modify File Attributes
Inquire to File Entries
Utility Functions …
Data Dictionary Utilities …
Transfer Entries
Other Options …
Select VA FileMan Option: ENTER or Edit File Entries
Input to what File: BEH MEASUREMENT CONTROL// (40 entries)
EDIT WHICH FIELD: ALL// LOW VALUE
THEN EDIT FIELD: HIGH VALUE
THEN EDIT FIELD:
Select BEH MEASUREMENT CONTROL: BLOOD PRESSURE BP
LOW VALUE: 90/40// <– here you can type a different low value that you desire
HIGH VALUE: 200/100// <– here you can type a different high value that you desire