1. First Change the TYPE field in the Laboratory Test file in Fileman to “NEITHER” to prevent the lab test from being ordered in the Laboratory package.
Enter or Edit File Entries
Print File Entries
Search File Entries
Modify File Attributes
Inquire to File Entries
Utility Functions …
Data Dictionary Utilities …
Transfer Entries
Other Options …
Select VA FileMan <PROD> Option: enter or Edit File Entries
Input to what File: ORDERABLE ITEMS// LABORATORY TEST (3961 entries)
EDIT WHICH FIELD: ALL// TYPE
THEN EDIT FIELD:
Select LABORATORY TEST NAME: XXXC-REACTIVE PROTEIN, HS (PacLab)
TYPE: NEITHER//
2. Set an Inactive date in the ORDERABLE ITEM file in Fileman to prevent the test being ordered in CareVue.
Enter or Edit File Entries
Print File Entries
Search File Entries
Modify File Attributes
Inquire to File Entries
Utility Functions …
Data Dictionary Utilities …
Transfer Entries
Other Options …
Select VA FileMan <PROD> Option: enter or Edit File Entries
Input to what File: ORDERABLE ITEMS// (9600 entries)
EDIT WHICH FIELD: ALL// INACTIVATED
THEN EDIT FIELD:
Select ORDERABLE ITEMS NAME: XXXC-REACTIVE PROTEIN, HS (PacLab)
INACTIVATED: <– This is a date and time for inactivating this item. If this field has a value, this item will not be available to select for ordering after this date.